DF Serie - Hanyoung - Controles de Temperatura Digital
- Fabricante: Hanyoung Nux
- Código de Producto: DF Serie
- Existencia: Disponible
Control de Temperatura Digital DF Serie
Características principales:
- Control proporcional o ON/OFF
- Simple selección de temperatura
- Simple selección de temperatura (SUB)
![]() | ![]() |
Suffix code
| Model | Code | Information | |||||
| DF | Economical Digital temperature controller | ||||||
| Dimension | 2 | 48(W) × 96(H) mm | |||||
| 4 | 48(W) × 48(H) mm (socket type, 8 pin) | ||||||
| Control Type | F | ON/OFF control | |||||
| P | Proportional control | ||||||
| Input | K | K thermocouple | |||||
| J | J thermocouple | ||||||
| D | RTD KPt 100 Ω | ||||||
| P | RTD Pt 100 Ω (IEC) | ||||||
| V | 1 - 5 V d.c | ||||||
| C | 4 - 20 mA d.c | ||||||
| Control output | M | Relay | |||||
| C | Current output (4 - 20 mA d.c) | ||||||
| S | S.S.R (voltage pulse output, 12 V d.c) | ||||||
| Auxiliary output (SUB) ? only with DF2 | N | None | |||||
| O | High deviation | ||||||
| P | Low deviation | ||||||
| W | High/Low deviation | ||||||
| Control action (internal selection) | R | Reverse action (heating control) | |||||
| D | Direct action (cooling control) | ||||||
| Range code | Refer to the range and input code | ||||||
| * Model DF4 selects proportional control/ON-OFF control by using internal deep switch. |
| * Model DF4 requires displaying voltage power such as for 220 V and for 110 V. |
| Classification | code | DF2 | DF4 / DF4T | ||
| Input type | Range (°C) | Input type | Range (°C) | ||
| Thermocouple | 4 | K, J | - | K, J | 0 ~ 199 |
| 5 | 0 ~ 199 | 0 ~ 299 | |||
| 6 | 0 ~ 299 | 0 ~ 399 | |||
| 7 | 0 ~ 399 | 0 ~ 599 | |||
| 8 | - | K | 0 ~ 799 | ||
| RTD | 1 | Pt100 Ω | -99 ~ 99 | Pt100 Ω | - |
| 2 | - | -99 ~ 99 | |||
| 3 | - | 0 ~ 99 | |||
| 4 | 0 ~ 99 | 0 ~ 199 | |||
| 5 | 0 ~ 199 | 0 ~ 299 | |||
| 6 | 0 ~ 299 | 0 ~ 399 | |||
| 7 | 0 ~ 399 | - | |||
| DC voltage | - | 1 - 5 V DC | 0 ~ 99 | 1 - 5 V DC | 0 ~ 99 |
| DC current | - | 4 - 20 mA DC | 0 ~ 99 | 4 - 20 mA DC | 0 ~ 99 |
Specification
| Model | DF2 | DF2 (SUB) | DF4 | ||||
| Appearance |
|
|
| ||||
| W × H × D (mm) | 48 × 96 × 100 | 48 × 96 × 100 | 48 × 48 × 100 | ||||
| Power voltage | 110 / 220 V a.c (50/60 Hz) | ||||||
| Power consumption | 3 VA | 4 VA | 3 VA | ||||
| Input |
| ||||||
| Control output |
| ||||||
| Control action | - | Proportional or ON/OFF control | - | ||||
| Alarm | Relay contact : 250VAC 3A | ||||||
| Setting | By B.C.D S/W | ||||||
| Permissible input resistance | Thermocouple:Max. 250 Ω, R.T.D : Max. 10 Ω | ||||||
| Display range | Setting value | ||||||
| Display | Digital indicatpr | ||||||
| Setting and display accuracy | Display ±0.5 % of F.S Range, Max. Set value ±1.0 % of F.S | ||||||
| Hysteresis | 0.2 % F.S (fixing), ON/OFF control. | ||||||
| Proportional cycle | Relay contact : 25 ~ 30 sec SSR : 2 ~ 4 sec | ||||||
| Reset range | ±1.5% of Max. Range | ||||||
| Dielectric strength | 2,000 V AC 50/60 Hz for 1 minute (Primary terminal-secondary terminal) | ||||||
| Vibration | Resistance | 2 - 55Hz, X, Y, Z each positions for 10 minutes | |||||
| Durability | 10 - 55 Hz, 0.76mm, X, Y, Z each positions for 2 hours | ||||||
| Shock | Resistance | 100 ㎨ 6 positions, Each 3 times | |||||
| Durability | 300 ㎨ 6 positions, Each 3 times | ||||||
| Life | Mechanical | More than 10 millions times | |||||
| Electrial | More than 0.3 millions times | ||||||
| Ambient temperature and humidity | 0 ~ 50 °C(32 ~ 122 °F) · 35 ~ 85 % R.H. (Without condensation) | ||||||