Categorías

  • Categorías
  • Alarmas / Terminales / Otros
  • Alarmas
  • Alarmas Electrónicas
  • Cajas Botoneras
  • Conectores
  • Portafusibles
  • Terminales
  • Botoneras / Pedales Eléctricos / Palancas de Mando
  • Botoneras
  • Palancas de Mando
  • Pedales Eléctricos
  • Botones
  • Interruptores de Contacto
  • Contadores / Temporizadores
  • Contador Digital
  • Contador y Temporizador
  • Temporizador Analógico
  • Temporizador Digital
  • Control de Nivel
  • Controles de Temperatura
  • Especializados
  • Generales
  • Indicadores
  • Otros
  • PID
  • Programables
  • Interruptores principales / Estación de Mando / Selector
  • Estaciones de Mando
  • Interruptores Principales
  • Selectores
  • Medidores de panel
  • Multifunción
  • Multímetros
  • Wattmetros
  • Micro Switch/Switch de Límite
  • Micro Switch
  • Switch de Límite
  • Productos Nuevos
  • Registradores Gráficos
  • Monocanal
  • Multi Canal
  • Sensores/Encoders
  • Amplificadores de Sensores
  • Cables de Conexión
  • Encoders
  • Sensores de Área
  • Sensores de Fibra Óptica
  • Sensores de Proximidad
  • Sensores Fotoeléctricos
  • Torretas / Luces Indicadoras
  • Luces Indicadoras
  • Torretas
  • TPR/SSR/SMPS
  • Disipadores de Calor
  • Fuentes de Alimentación
  • Reguladores de Potencia Tipo Tiristor
  • Relevadores Estado Sólido

Llámanos: (81) 8359-7570 / 8358-8687

E-mail: contacto@ssint.com.mx

WM3 - Hanyoung - Medidor de Panel

WM3 - Hanyoung - Medidor de Panel

  • Fabricante: Hanyoung Nux
  • Código de Producto: WM3
  • Existencia: Disponible

Medidores de Panel WM3

Características principales:
- Wattmetro digital
- Medición RMS
- Conexión directa
- Visualización de la medición de voltaje y corriente (4 dígitos, máximo 9999)
- Voltaje 0~220VCA, 0~5A CA
- Salida (Relé, Corriente 4-20mA, TR, RS485)


Suffix code

Model code Information
WM - Digital Wattmeter
External dimension 3       External dimension(96mm X 48mm)
Type of phase 1     Single phase 2 W
Measurement input specification 01(※)   XXX: 5A (Ageneral C.T uses) Current transfrom ratio setup(C.Texcluded)
02(※)   XXX: 1A (Ageneral C.T uses) Current transfrom ratio setup(C.Texcluded)
03   0 ~ 2.5A(H-1W C.T uses) 0-500.0 W Max(C.T included)
04   0 ~ 5A(H-1W C.T uses) 0-1100 W Max(C.T included)
05   0 ~ 10A(H-1W C.T uses) 0-2200 W Max(C.T included)
06   0 ~ 15A(H-1W C.T uses) 0-3300 W Max(C.T included)
07   0 ~ 30A(H-2W C.T uses) 0-6600 W Max(C.T included)
08   0 ~ 50A(H-2W C.T uses) 0-11.00 KW Max(C.T included)
09   0 ~ 80A(H-4W C.T uses) 0-17.60 K W Max(C.T included)
10   0 ~ 100A(H-4W C.T uses) 0-22.00 K W Max(C.T included)
11   0 ~ 150A(H-5W C.T uses) 0-33.00 KW Max(C.T included)
12   0 ~ 200A(H-5W C.T uses) 0-44.00 K W Max(C.T included)
Output specification(option) N only for display
0 Relay (HI, GO, LO) + Current output(4-20 ㎃)
1 Relay(HI, GO, LO)
2 NPN TR(HI, GO, LO) + Current output(4 - 20 ㎃)
3 PNP TR(HI, GO, LO) + Current output(4 - 20 mA)
4 NPN TR(HI, GO, LO) + RS485 Output
5 PNP TR(HI, GO, LO) + RS485 Output
 

C.T( Current Transfomers)
※ Spec 01 and 02 use general current transformer and users must set current transform ratio(Refer to setting method of current transform ratio)
spec 03 ~ 12 are accurate measuring wattmeter which uses H series C.T of accuracy 0.2%.
 

Cautious)spec of 03 ~ 12 cannot use general current transformer and it is unnecessary to set current transform ratio .
- Type of measuring spec is single phase 2 lines and when current transformer is 200 A : 5 A, then please purchase WM2-101 and use it. (if current transformer is 200A : 1A then please use WM3-101)
- Initial current transformer setting for spec 01 and 02 is set with 100 A
- Output spec 0 ~ 5 are option
- PV (output displaying value)
- RS485 output spec is coming soon

 


Specification

Power Supply
   100 ~ 240 V a.c 50-60 ㎐ Allowable percentage of voltage difference : 85~110%
Power consumption
   6 V A
Display type
   7 Segment LED display
Insulation resistance    Above 100 ㏁(500 V d.c mega standard) between external terminal and case
Max voltage durability    Above 2000 V a.c, per 1 min between external terminal and case
Max noise durability    Square wave noise due to noise simulator, pulse width 1 ㎲ ± 1000V
Max vibration
durability
   10-50 ㎐ Malfunction, double amplitude in each 0.5mm X, Y, Z direction for 1 hour
   10-50 ㎐ Durability, double amplitude in each 0.75mm X, Y, Z direction for 2 hours
Max shock durability    100 ㎨ Malfunction each X, Y, Z direction for 3 times
   300 ㎨ Durability each X, Y, Z direction for 2 times
Ambient temperature    -10 ~ 55℃ (No freezing allowed)
Ambient humidity    Relative humidity 35 ~ 85% R.H
Ambient environment    Corrosiveness gas not allowed
Storage ambient temperature    -20 ~ 65% ℃ (No freezing allowed)
Relay life    Mechanically : 20,000,000 ps Min. Electrically : 100,000 ps Min.
Weight    Approximately 300g

Measurement type
   Cycle measuring type, cos ø =LEAD 0.8 - 1 - LAG 0.8
Display cycle
   Min. : 0.1 second, Max. 2 second
Displayable number of digits
   -1999 ~ 9999 (4 digits standard)
Measuring list
   Power consumption
Input range
   0-240 V a.c 50 - 60 ㎐
Function of decimal point
   Selection due to internal parameter
Function of scaling
   Function of displaying temporal numerical values which is converted from measured (input)
Hold function
   Automatic max and min Peak value detection hold and external hold
Control
   Displaying value hold
Other functions
  • • Remote local switching(communication output type)
  • • Display max / min value by front key
  • • Function of handling average value and delaying displaying cycle
  • • Changing comparative output setting
  • • Set value changing protective function
Output type
  • • Relay contact output
  • •Transistor output (NPN, PNP)
  • • Current output(4-20㎃)
  • • Communication output(RS485)

Etiquetas: WM3