Medidores de Panel WM3
Características principales:
- Wattmetro digital
- Medición RMS
- Conexión directa
- Visualización de la medición de voltaje y corriente (4 dígitos, máximo 9999)
- Voltaje 0~220VCA, 0~5A CA
- Salida (Relé, Corriente 4-20mA, TR, RS485)
| |
Suffix code
Model | code | Information |
WM | - | | | | Digital Wattmeter |
External dimension | 3 | | | | External dimension(96mm X 48mm) |
Type of phase | 1 | | | Single phase 2 W |
Measurement input specification | 01(※) | | XXX: 5A (Ageneral C.T uses) | Current transfrom ratio setup(C.Texcluded) |
02(※) | | XXX: 1A (Ageneral C.T uses) | Current transfrom ratio setup(C.Texcluded) |
03 | | 0 ~ 2.5A(H-1W C.T uses) | 0-500.0 W Max(C.T included) |
04 | | 0 ~ 5A(H-1W C.T uses) | 0-1100 W Max(C.T included) |
05 | | 0 ~ 10A(H-1W C.T uses) | 0-2200 W Max(C.T included) |
06 | | 0 ~ 15A(H-1W C.T uses) | 0-3300 W Max(C.T included) |
07 | | 0 ~ 30A(H-2W C.T uses) | 0-6600 W Max(C.T included) |
08 | | 0 ~ 50A(H-2W C.T uses) | 0-11.00 KW Max(C.T included) |
09 | | 0 ~ 80A(H-4W C.T uses) | 0-17.60 K W Max(C.T included) |
10 | | 0 ~ 100A(H-4W C.T uses) | 0-22.00 K W Max(C.T included) |
11 | | 0 ~ 150A(H-5W C.T uses) | 0-33.00 KW Max(C.T included) |
12 | | 0 ~ 200A(H-5W C.T uses) | 0-44.00 K W Max(C.T included) |
Output specification(option) | N | only for display |
0 | Relay (HI, GO, LO) + Current output(4-20 ㎃) |
1 | Relay(HI, GO, LO) |
2 | NPN TR(HI, GO, LO) + Current output(4 - 20 ㎃) |
3 | PNP TR(HI, GO, LO) + Current output(4 - 20 mA) |
4 | NPN TR(HI, GO, LO) + RS485 Output |
5 | PNP TR(HI, GO, LO) + RS485 Output |
C.T( Current Transfomers) ※ Spec 01 and 02 use general current transformer and users must set current transform ratio(Refer to setting method of current transform ratio) spec 03 ~ 12 are accurate measuring wattmeter which uses H series C.T of accuracy 0.2%. Cautious)spec of 03 ~ 12 cannot use general current transformer and it is unnecessary to set current transform ratio . - Type of measuring spec is single phase 2 lines and when current transformer is 200 A : 5 A, then please purchase WM2-101 and use it. (if current transformer is 200A : 1A then please use WM3-101) - Initial current transformer setting for spec 01 and 02 is set with 100 A - Output spec 0 ~ 5 are option - PV (output displaying value) - RS485 output spec is coming soon |
Specification
Power Supply | 100 ~ 240 V a.c 50-60 ㎐ Allowable percentage of voltage difference : 85~110% | |
Power consumption | |
Display type | |
Insulation resistance | Above 100 ㏁(500 V d.c mega standard) between external terminal and case |
Max voltage durability | Above 2000 V a.c, per 1 min between external terminal and case |
Max noise durability | Square wave noise due to noise simulator, pulse width 1 ㎲ ± 1000V |
Max vibration durability | 10-50 ㎐ Malfunction, double amplitude in each 0.5mm X, Y, Z direction for 1 hour 10-50 ㎐ Durability, double amplitude in each 0.75mm X, Y, Z direction for 2 hours |
Max shock durability | 100 ㎨ Malfunction each X, Y, Z direction for 3 times 300 ㎨ Durability each X, Y, Z direction for 2 times |
Ambient temperature | -10 ~ 55℃ (No freezing allowed) |
Ambient humidity | Relative humidity 35 ~ 85% R.H |
Ambient environment | Corrosiveness gas not allowed |
Storage ambient temperature | -20 ~ 65% ℃ (No freezing allowed) |
Relay life | Mechanically : 20,000,000 ps Min. Electrically : 100,000 ps Min. |
Weight | Approximately 300g |
Measurement type | Cycle measuring type, cos ø =LEAD 0.8 - 1 - LAG 0.8 | |
Display cycle | Min. : 0.1 second, Max. 2 second | |
Displayable number of digits | -1999 ~ 9999 (4 digits standard) | |
Measuring list | |
Input range | |
Function of decimal point | Selection due to internal parameter | |
Function of scaling | Function of displaying temporal numerical values which is converted from measured (input) | |
Hold function | Automatic max and min Peak value detection hold and external hold | |
Control | |
Other functions | - • Remote local switching(communication output type)
| - • Display max / min value by front key
| - • Function of handling average value and delaying displaying cycle
| - • Changing comparative output setting
| - • Set value changing protective function
| |
Output type | | - •Transistor output (NPN, PNP)
| | - • Communication output(RS485)
| |