Power Supply |
100 ~ 240 V AC 50/60 Hz |
Power Consumption |
Approx. 3.5 VA (240 V AC) |
Voltage for Sensor |
12 V DC ± 10 % 80 mA |
Measurement Accuracy |
• Mode F1, F4, F10, F11, F12, F13: FS ± 0.05rdg ± 1 dig |
• Mode F2, F3, F5, F6: FS ± 0.01 %rdg ± 1 dig |
|
Measurement Range |
• Mode F1, F10, F11, F12, F13: 0.0005 Hz ~ 50 Hz |
• Mode F2, F5, F6: 0.01 s ~ 3.200 s |
• Mode F3, F4: 0.02 s ~ 3.200 s |
• Mode F7, F8, F9: 0 ~ 4 x 109 Count |
|
Input Signal |
Non-Contact Input : Max. 50 Hz (ON/OFF width for each above 10 ) |
(ON voltage: 4.5 V ~ 24 V, OFF voltage: 0 ~ 1.0 V) |
Contact Input : Max. 50 KHz (ON/OFF width for each above 8.3 ms) |
(12 V DC, able to switch the current of 2 mA sufficiently) |
|
Max. Displayable Digits |
5 digits (-19999 ~ 99999) |
Display Method |
7 Segment |
Display Cycle |
0.05/0.5/1/2/8sec(each setting for each bank/batch setting selection function) |
|
Hysteresis |
0 ~ 9999 (each setting for each bank/batch setting |
selection function, applicable only for output type) |
|
Functions |
• Auto Zero Time Setting Function |
• Parameter Lock Function |
• Display Cycle Setting Function |
• 4 Steps Bank Setting Function |
• Time Unit Selection Function(each setting for each bank/batch setting selection function) |
• Remote/Local Conversion Function(applicable only for communication output type) |
• Current Output Range Selection Function(applicable only for current output type) |
• Max. Min. Peak Value 10 Steps Memory Function |
(Max.: 4 steps save, Average Value Save / Min.: 4 steps save, Average Value Save) |
• Start Compensation Timer Function |
• Comparative Output Function (HH, H, GO, L, LL) |
• Electricity Failure Compensation (applicable only for F9) |
|
Output |
Output Types |
• Transistor Output (NPN Open Collector Output):Comparative, Alarm Output |
• Relay Output (HH, H, GO, L, LL) |
• BCD Dynamic Displayed Value Output Function |
• PV Transfer Output (4 ~ 20 mA DC): Displayed Value Output |
• RS485 Communication Output (32 channels): Displayed |
Value Output, PC Setting Function (See the Output Specification) |
|
Relay (main) |
277 V AC 3 A, 30 V DC 3 A MAX. |
Non-Contact (main) |
NPN Open Collector 12 ~ 24 V DC 30 mA MAX. |
BCD |
NPN Open Collector 12 ~ 24 V DC 30 mA MAX. |
Current |
4 ~ 20 mA DC Indicated Value(PV) Output, Resistive Load : below 790 Ω |
Current Input |
4 ~ 20 mA DC Input |
RS-485 Communication |
32 channels, two-way communication is possible |
Memory |
Non-volatile Memory (10 years) |
Insulation Resistance |
Above 10 MΩ (at 500 V DC mega) Between electrically |
chargeable part and non-electrically chargeable part |
|
Noise Immunity |
By noise simulator, square-shaped wave noise (pulse width 1µs) ±2000 V |
Life Expentancy |
Mechanical |
Above 100 thousand times(250 V AC 3 A, switching: 20 times/1 minute) |
|
Electrical |
Above 5 million times (switching: 180 times/1 minute) |
Dielectric Strength |
2000 V AC 60 Hz for 1 minute |
(between AC power terminal and case, between AC terminal and measurement input terminal) |
|
Vibration Resistance |
Durability |
10 ~ 55 Hz double amplitude width 0.75 mm in each X Y Z direction for 2 hours |
|
Malfunction |
10 ~ 55 Hz double amplitude width 0. 5 mm in each X Y Z direction for 10 minutes |
|
Shock Resistance |
Durability |
300 m/s² (approx. 30G) in each X Y Z direction for 3times |
Malfunction |
100 m/s² (approx. 10G) in each X Y Z direction for 3times |
Operating Ambient Temperature |
-10 ~ +50 °C (without condensation) |
Storage Temperature |
-20 ~ +60 °C (without condensation) |
Operating Ambient Humidity |
35 ~ 85 % RH |
Weight |
Approx. 135 g |