TPR-2M - Hanyoung - Reguladores de Potencia tipo Tiristor
- Fabricante: Hanyoung Nux
- Código de Producto: TPR-2M
- Existencia: Disponible
Reguladores de Potencia tipo Tiristor TPR-2M
Características principales:
- Varios métodos de control disponibles en función de las cargas
- Diferentes funciones de protección (Interruptor de calentador, sobre intensidad de corriente, disipador de calor de sobrecalentamiento, SCR corto circuito)
- Formado por dos unidades de conmutación con disipador de calor, elemento de potencia y sistema electrónico de control respectivamente
- Soft Start
Suffix code
Model | Code | Information | ||||
TPR-2M | Slim type Single phase power regulator | |||||
Type | E | Economical type | ||||
S | Advanced type | |||||
Rated current | 25 | 25 A | ||||
35 | 35 A | |||||
Power supply voltage | L | 100 - 240 V AC | ||||
H | 100 - 440 V AC (Advanced type) | |||||
Option | C | 4 - 20 mA DC | Economical(E) : Standard Advanced(S) : Option | |||
V | 1 - 5 V DC | |||||
O | ON/OFF |
※ Please supply 100 – 240 V AC (Low) / 24 V DC (High) to the control unit of the power controller (Thyristor) separately. |
Specification
Model | Economical | Advanced model | |||
Low voltage | Low voltage | High voltage | |||
TPR-2ME25L | TPR-2MS25L | TPR-2MS25H | |||
TPR-2ME35L | TPR-2MS35L | TPR-2ME35H | |||
Power supply voltage | 100 - 240 V a.c. | 100 - 440 V a.c. | |||
Circuit input power | 100 - 240 V a.c. 3 W | 24 V d.c. 1 W | |||
Power frequency | 50 / 60 Hz (Dual usage) | ||||
Rated current | 25 A / 35 A | ||||
Control input | Current input | 4 - 20 ㎃ d.c. (Impedance : 100 Ω) (Basic packages) | 4 - 20 ㎃ d.c. (Impedance : 100 Ω) (Option) | ||
Voltage input | 0 - 5 V d.c (Basic packages) | 1 - 5 V d.c. (Option) | |||
Voltage input | ON/OFF (Basic packages) | ON/OFF (Option) | |||
External V.R | External V.R (10 ㏀) | - | |||
Control method | Phase control (Basic), Variable cycle control (Order made) | ||||
Start type | SOFT START (60 sec), SOFT UP/DOWN (15 sec) / Adjust start time by SOFT V.R | ||||
Output voltage | More than 98 % of the power supply voltage ( In case of maximum current input ) / Output limitation control by Power V.R | ||||
Alarm function | Current error (CE) | - | O (Relay contact output) | ||
Over temperature (OT) | - | ||||
Power error / Heater break(PE) | O | ||||
SCR short (PE) | - | ||||
Display method (LED) | Output | FIRE : Lighting in proportion of output | |||
Power | Light on when power connect to circuit | - | |||
Alarm | - | CE (CURRENT ERROR) : Light on when 45 A over current | |||
- | OT (OVER TEMP) : Light on when Heat sink temperature is above 85 ℃ | ||||
PE (POWER ERROR) : Power error, Heater break | |||||
Cooling method | Natural cooling | ||||
Weight | approx. 322 g |
Explanation for LED status display |
TPR-2MS |
Name | LED Color | Explanation |
FIRE | Green | Output lamp (Lighting in proportion of output) |
CE (Current error) | Green | Light on when over current situation |
OT (Over temp) | Green | Light on when heat sink over temperature |
PE(Power error) | Red | Light on when Power error, Heater break or SCR short |
TPR-2ME |
Name | LED Color | Explanation |
FIRE | Green | Output lamp (Lighting in proportion of output) |
POWER | Red | Light on when power connect to circuit |
SOFT | Red | Light on when SOFT VR turn right for Soft start, Soft up/down. |
PE(Power error) | Red | Power error, Heater break |
Explanation for alarm output |
name | Explanation |
Over current | 45 A (r.m.s) over current |
Over temperature head sink | Heat sink temperature is above 85’C |
Power error | Circuit power is connected but load power is not connected |
Heat break | Load is disconnected |
SCR short | Without control output, current flows continuously |