HY-2000 - Hanyoung - Control de Temperatura Ánalogo
- Fabricante: Hanyoung Nux
- Código de Producto: HY-2000
- Existencia: Disponible
Control de Temperatura Análogo HY-2000
Características principales:
- Control proporcional o ON/OFF
- Simple selección de temperatura
- Ajuste por perilla (corrección, comprobación e intercambio simple)
Suffix code
[ HY-1000 / HY-2000 / HY-3000 ] |
Model | Code | Information | |||||
HY- / AF- | Standard Model HY-1000 / HY-2000 / HY-3000 / AF1 | ||||||
Adjusting action | F | 2-Position Control(ON / OFF) | |||||
P | Proportional action | ||||||
Input | K | K (CA) | |||||
J | J (IC) | ||||||
R | R (PR 13%) | ||||||
D | Pt100 Ω (KS Standards) | ||||||
P | Pt100 Ω (DIN Standards) | ||||||
V | *1 - 5 V d.c | ||||||
C | *4 - 20 mA d.c | ||||||
Control Output | M | Relay contact | |||||
C | *Current (4 - 20 mA d.c) | ||||||
S | *SSR driving (Voltage Pulse 12 V d.c) | ||||||
Alarm Output or Operation | N | None | |||||
O | High Limit Operation Alarm Output | ||||||
P | Low Limit Operation Alarm Output | ||||||
W | High / Low Limit Operation Alarm Output | ||||||
Control action | R | Reverse action Control (for Heating Control) | |||||
D | Direct action Control (for Cooling Control) | ||||||
Range code | Standard Range Code Number Selection |
* Non-display product does not have the feature |
[ HY-1000 / HY-2000 / HY-3000 ] |
Model / Code No. | HY-1000 | HY-2000 / 3000 | AF1 | |||
Input | Temp. Range | Input | Temp. Range | Input | Temp. Range | |
1 | Pt | -50 ~ 50 | Pt | -99 ~ 99 | ||
2 | Pt | -50 ~ 100 | ||||
3 | Pt | 0 ~ 100 | Pt | 0 ~ 99 | ||
4 | Pt, K, J | 0 ~ 100 | Pt, K | 0 ~ 199 | ||
5 | Pt, K | 0 ~ 200 | Pt, K, J | 0 ~ 200 | Pt, K | 0 ~ 299 |
6 | Pt, K | 0 ~ 300 | Pt, K, J | 0 ~ 300 | Pt, K | 0 ~ 399 |
7 | Pt, K | 0 ~ 400 | Pt, K, J | 0 ~ 400 | ||
8 | K | 0 ~ 600 | K | 0 ~ 600 | ||
9 | K | 0 ~ 800 | K | 0 ~ 800 | ||
10 | K | 0 ~ 1200 | ||||
11 | K | 0 ~ 1200 | ||||
12 | R | 0 ~ 1600 |
Specification
[ HY-1000 / HY-2000 / HY-3000 ] |
Model | HY-1000 | HY-2000 | HY-3000 |
Appearance | |||
Power supply voltage | 110 V a.c / 220 V a.c 60 Hz | ||
Permissible Voltage Fluctuation Range | Rated Voltage ±10 % | ||
Consumption Power | Approx. 3 VA max | ||
Input | Thermocouple, Resistive | Thermocouple, Resistive, DC Current, DC Voltage | |
Adjusting Sensitivity | ±0.2 % (fixed) of Max. Range | ||
Control Method | Time Proportional Control, ON/OFF Control | ||
Setting Method | Analog Setting | ||
Display Method | Non-Display | Deviation Display | |
Control Output | Relay Output :Capacity 250 V a.c 3 A | Relay Output : capacity 250 V a.c 3 A SSR Output : 12 V d.c Load Resistance : Above 800 Ω | |
Setting Accuracy | Within ± 2.0 % of Max. Range | ||
Display Accuracy | HY-1000 : ±1.0 % (fixed) of Max. Range HY-2000 : ±2.0 % (fixed) of Max. Range | ±2.5 % (fixed) of Max. Range | |
Proportional Band | 3 % of Max. Range (fixed) | ||
Proportional Cycle | Relay Output : Approx. 20 sec, SSR Output : Approx. 2 sec | ||
External Input Resistance | Thermocouple : Below 100 Ω, Resistive : Below 10 Ω Per 1 Wire (The Resistance of Each Wire Should be the Same.) | ||
Reset Range | None | ||
Alarm Setting Range | - | ||
Alarm Output Adjusting Sensitivity | - | ||
Hysteresis | Thermocouple : 1.2 °C (Below 600 °C), 2.4 °C (Above 600 °C)35 Resistive : 0.6 °C (Below 200 °C), 1.2 °C (Above 200 °C) | ||
Dielectric Strength | 2000 V a.c 60 Hz for 1 Minute | ||
Relay Life Expectancy | Mechanical : Above 10 Millions Times, Electrical : Above 100 Thousands Times (250 V a.c, 3 A Resistive Load) | ||
Operating Ambient Temperature/Humidity | 0 ~ 50 °C, 35 ~ 85 % R.H (Without Condensation) | ||
Weight | HY-1000 : 358 g (Including Brackets) | HY-2000, 3000 : 558 g (Including Brackets) |
Etiquetas: HY-2000