HY-2000 - Hanyoung - Control de Temperatura Ánalogo
- Fabricante: Hanyoung Nux
- Código de Producto: HY-2000
- Existencia: Disponible
Control de Temperatura Análogo HY-2000
Características principales:
- Control proporcional o ON/OFF
- Simple selección de temperatura
- Ajuste por perilla (corrección, comprobación e intercambio simple)
Suffix code
| [ HY-1000 / HY-2000 / HY-3000 ] |
| Model | Code | Information | |||||
| HY- / AF- | Standard Model HY-1000 / HY-2000 / HY-3000 / AF1 | ||||||
| Adjusting action | F | 2-Position Control(ON / OFF) | |||||
| P | Proportional action | ||||||
| Input | K | K (CA) | |||||
| J | J (IC) | ||||||
| R | R (PR 13%) | ||||||
| D | Pt100 Ω (KS Standards) | ||||||
| P | Pt100 Ω (DIN Standards) | ||||||
| V | *1 - 5 V d.c | ||||||
| C | *4 - 20 mA d.c | ||||||
| Control Output | M | Relay contact | |||||
| C | *Current (4 - 20 mA d.c) | ||||||
| S | *SSR driving (Voltage Pulse 12 V d.c) | ||||||
| Alarm Output or Operation | N | None | |||||
| O | High Limit Operation Alarm Output | ||||||
| P | Low Limit Operation Alarm Output | ||||||
| W | High / Low Limit Operation Alarm Output | ||||||
| Control action | R | Reverse action Control (for Heating Control) | |||||
| D | Direct action Control (for Cooling Control) | ||||||
| Range code | Standard Range Code Number Selection | ||||||
| * Non-display product does not have the feature |
| [ HY-1000 / HY-2000 / HY-3000 ] |
| Model / Code No. | HY-1000 | HY-2000 / 3000 | AF1 | |||
| Input | Temp. Range | Input | Temp. Range | Input | Temp. Range | |
| 1 | Pt | -50 ~ 50 | Pt | -99 ~ 99 | ||
| 2 | Pt | -50 ~ 100 | ||||
| 3 | Pt | 0 ~ 100 | Pt | 0 ~ 99 | ||
| 4 | Pt, K, J | 0 ~ 100 | Pt, K | 0 ~ 199 | ||
| 5 | Pt, K | 0 ~ 200 | Pt, K, J | 0 ~ 200 | Pt, K | 0 ~ 299 |
| 6 | Pt, K | 0 ~ 300 | Pt, K, J | 0 ~ 300 | Pt, K | 0 ~ 399 |
| 7 | Pt, K | 0 ~ 400 | Pt, K, J | 0 ~ 400 | ||
| 8 | K | 0 ~ 600 | K | 0 ~ 600 | ||
| 9 | K | 0 ~ 800 | K | 0 ~ 800 | ||
| 10 | K | 0 ~ 1200 | ||||
| 11 | K | 0 ~ 1200 | ||||
| 12 | R | 0 ~ 1600 | ||||
Specification
| [ HY-1000 / HY-2000 / HY-3000 ] |
| Model | HY-1000 | HY-2000 | HY-3000 |
| Appearance | ![]() | ![]() | ![]() |
| Power supply voltage | 110 V a.c / 220 V a.c 60 Hz | ||
| Permissible Voltage Fluctuation Range | Rated Voltage ±10 % | ||
| Consumption Power | Approx. 3 VA max | ||
| Input | Thermocouple, Resistive | Thermocouple, Resistive, DC Current, DC Voltage | |
| Adjusting Sensitivity | ±0.2 % (fixed) of Max. Range | ||
| Control Method | Time Proportional Control, ON/OFF Control | ||
| Setting Method | Analog Setting | ||
| Display Method | Non-Display | Deviation Display | |
| Control Output | Relay Output :Capacity 250 V a.c 3 A | Relay Output : capacity 250 V a.c 3 A SSR Output : 12 V d.c Load Resistance : Above 800 Ω | |
| Setting Accuracy | Within ± 2.0 % of Max. Range | ||
| Display Accuracy | HY-1000 : ±1.0 % (fixed) of Max. Range HY-2000 : ±2.0 % (fixed) of Max. Range | ±2.5 % (fixed) of Max. Range | |
| Proportional Band | 3 % of Max. Range (fixed) | ||
| Proportional Cycle | Relay Output : Approx. 20 sec, SSR Output : Approx. 2 sec | ||
| External Input Resistance | Thermocouple : Below 100 Ω, Resistive : Below 10 Ω Per 1 Wire (The Resistance of Each Wire Should be the Same.) | ||
| Reset Range | None | ||
| Alarm Setting Range | - | ||
| Alarm Output Adjusting Sensitivity | - | ||
| Hysteresis | Thermocouple : 1.2 °C (Below 600 °C), 2.4 °C (Above 600 °C)35 Resistive : 0.6 °C (Below 200 °C), 1.2 °C (Above 200 °C) | ||
| Dielectric Strength | 2000 V a.c 60 Hz for 1 Minute | ||
| Relay Life Expectancy | Mechanical : Above 10 Millions Times, Electrical : Above 100 Thousands Times (250 V a.c, 3 A Resistive Load) | ||
| Operating Ambient Temperature/Humidity | 0 ~ 50 °C, 35 ~ 85 % R.H (Without Condensation) | ||
| Weight | HY-1000 : 358 g (Including Brackets) | HY-2000, 3000 : 558 g (Including Brackets) | |
Etiquetas: HY-2000