KX Serie - Hanyoung - Controles de Temperatura Digital
- Fabricante: Hanyoung Nux
- Código de Producto: KX Serie
- Existencia: Disponible
Control de Temperatura Digital KX Serie
Características principales:
- Entradas universales
- Selección de la posición del punto decimal
- Operación de salida: selección de funcionamiento directo o inverso
- Sintonización automatica PID
- Alarma de ruptura de resistencia
- 2 alarmas (alta y baja)
Suffix code
Model | Code | Information | |||||
KX | - | Digital Temperatrue Contoller | |||||
Dimension | 2N | 48(W) × 96(H) mm | |||||
3N | 96(W) × 48(H) mm | ||||||
4N | 48(W) × 48(H) mm | ||||||
7N | 72(W) × 72(H) mm | ||||||
9N | 96(W) × 96(H) mm | ||||||
4S | 48(W) × 48(H) mm | for 11 pin socket | |||||
Control output | M | Relay | |||||
S | SSR (Voltage pulse 12 V DC) | ||||||
C | SCR (Current 4 - 20 mA DC) | ||||||
Alarm output | C | * KX4N, KX4S selection only | ALH, ALL, LBA (1a common output) | ||||
E | * KX4S selection inhibited | ||||||
KX2N, KX3N, KX9N | ALH(1c), ALL(1a) | ||||||
KX7N, KX4N (option) | ALH(1a), ALL(1a) | ||||||
K | * KX4N, KX4S selection inhibited | ||||||
KX2N, KX3N, KX9N (optional) | ALH(1c), ALL(1a), LBA(1a) | ||||||
KX7N (optional) | ALH(1a), ALL(1a), LBA(1a) | ||||||
Retransmission output (Option) | A | * Only selectable with models given in the below KX4N-□C KX2N-□E, KX3N-□E, KX9N-□E KX2N-□K, KX3N-□K, KX9N-□K | Retransmission output(RET) 4 - 20 mA d.c | ||||
N | None | ||||||
Power Supply Voltage | A | 100 - 240 V a.c, 50 - 60 Hz | |||||
D | 24 V d.c (KX4S selection inhibited) |
* When using 4-20 mA input, attach 0.1 % of 250 Ω resistance to the input terminal of 1-5V d.c |
Specification
Model | KX9N | KX7N | KX2N | KX3N | KX4N(S) | |||||||||
Apperance | | | | | | |||||||||
W × H × D (mm) | 96 × 96 × 100 | 72 × 72 × 100 | 48 × 96 × 100 | 96 × 48 × 100 | 48 × 48 × 100 | |||||||||
Function |
| |||||||||||||
Power Voltage | 100 - 240 V a.c, 50 - 60 Hz (voltage fluctuation rate : ± 10 %) | |||||||||||||
Power Consumption | Below 11 VA max | Below 7 VA max | ||||||||||||
Input | Input type | Please refer to Input code | ||||||||||||
Sampling cycle | 250 ms | |||||||||||||
Indication accuracy | ±0.5 % (Please refer to Input type) | |||||||||||||
Allowable voltage | ±20 V d.c for 1 minute | |||||||||||||
Reference junction temperature | ±3.5 ?, 0 ~ 50 °C | |||||||||||||
Operation after input break | Up scale after input break, output OFF | |||||||||||||
Control Output | Relay | NO : 5 A 250 V a.c, 5 A 30 V d.c(Resistive load) NO : 3 A 250 V a.c, 1 A 30 V d.c(Resistive load) | ||||||||||||
Voltage output | ON voltage : More than 12 V d.c min Load resistance: 600 Ω min | |||||||||||||
Current output | Range : 4 - 20 mA d.c (±5%) Accuracy : ±0.2 mA Load resistance: 600 Ω max | |||||||||||||
Retransmission output | Range : 4 - 20 mA d.c (±5 %) Accuracy : ±0.2 mA Load resistance: 600 Ω max | |||||||||||||
Alarm output | 250 V a.c, 3 A (Resistive load) refer to connection diagram (contact) But, KX4N: 1a contact, 250 V a.c 1A (load resistance) | |||||||||||||
Contact input | OFF resistance : 10 ㏀ min ON resistance : 1 ㏀ max | |||||||||||||
Control | Method | PID control, ON/OFF | ||||||||||||
Output operation | Reverse action, Direct action | |||||||||||||
Anti-reset wind-up | Auto (A=0), 0.1 ~ 100.0 % | |||||||||||||
Insulation Resistance | 20 ㏁ min between 1st and 2nd terminals | |||||||||||||
Dielectric strength | 2,300 V a.c between 1st and 2nd terminals, for 1 minute | |||||||||||||
Operating environment | Temperature & Humidity | 0 ~ 50 °C, 35 ~ 85 % R.H.( With no condensation) | ||||||||||||
Environment | Please refer to safety information |